LUGB high pressure for steam flow meter
Basic Info
Model No.: LUGB serises
Product Description
1.Accuracy: Liquid Gas 1% Steam 1.5%
2.Temperature:-20oC to +350oC
3.Measure : Gas steam
LUGB Vortex Flow Meter/ high pressure for steam flow meter
inside nominal diameter (mm) | 25,40,50,65,80,100,125,150,200,250,300,(300~1000 plug-in) |
nominal pressure (MPa) | DN25-DN200 4.0(>4.0 order by agreement),DN250-DN300 1.6(>1.6 order by agreement) |
medium temperature (°C) | piezoelectric type:-40~260,-40~320;capacitance: -40~300, -40~400,-40~450(order by agreement) |
noumenon | 1Cr18Ni9Ti,(order by agreement if need Other material) |
vibrating acceleration | piezoelectric type:0.2g capacitance:1.0~2.0g |
range | ±1%R,±1.5%R,±1FS;plug-in:±2.5%R,±2.5%FS |
Range degree | 1:6~1:30 |
service voltage | sensor:+12V DC,+24V DC;transmitter:+12V DC ,+24V DC;battery supply feed:3.6V battery |
output signal | square wave pulse (non- battery supply feed):high level≥5V,low level≤1V;current:4~20mA |
loss coefficient | JB/T9249 Cd≤2.4 |
anti-explosion sign | Ben-an type:ExdⅡia CT2-T5 anti-explosion type:ExdⅡCT2-T5 |
Protection grade | ordinary type IP65 dive type IP68 |
environment condition | Tem-20°C~55°C,relative humidity 5%~90%,atm press 86~106kPa |
medium | gas,liquid,vapor |
transmission range | three-wire system flow sensor:≤300m,electric sign of two-wire system transmitter (4~20mA):load resistance≤750Ω |
f=StV/d I Factor: f-The Karman vortex street frequency which one side of vortex-maker St-Strouhal number(dimensionless number) V-mean flow rate d-the width of vortex-maker So, check the separate frequency of Karman vortex street to know the instant capacity(flow) .among, Strouhal number(St)is dimensionless number, Chart II Show the relation of, Strouhal number(St) & Reynolds number (Re) Straightness part in curve(St=0.17),free frequency & flow rate of vortex is direct ratio, it means flow sensor range. so just check out frequency (f),we can get the flow rate inside pipe, then as the flow rate(V) to take volume flow, the ratio record of impulse & volume, called as(K),as follow(2) K=N/Q(1/m³) (2) Model:K=instrument constant(1/m³). N=impulse number Q=volume flow(m³) Contact us if you need more details on High Pressure for Steam Flow Meter. We are ready to answer your questions on packaging, logistics, certification or any other aspects about High Pressure for Steam Flow Meter、High Pressure for Steam Flow Meter. If these products fail to match your need, please contact us and we would like to provide relevant information.