LDG Series acid flow meter (Electromagnetic flow meter)
Basic Info
Model No.: LDG
Product Description
2.no movable parts,no pressure loss
3.HART,RS-485,232,4~20mA,pulse output
4. Low cost
LDG Series acid flow meter( Electromagnetic Flow Meter) General Description Electromagnetic flowmeter suits for all kinds of liquids’ flow measuring such as electronic conductivity liquid, mud and slurry etc. on the basis of its min. conductivity. The result cannot be affected by temperature, pressure, viscosity and density. It can also be used for measuring corrosive material as long as the right material has been chosen for the lining material. Solid medium will not affect the result. Flow sensor and intelligent converter compact or separately composes a complete flowmeter. Application The main application area; Pure water, sewage water Electronic manufacture and assign Chemistry and industrial medicine Food industry Product Description LDG Series Electromagnetic acid flow meter Fluid: Liquid with conductivity Great resistance to causticity No moving Part Less requirements on (straight pipe) meter run
Appearance | |||||
Model | LDG Series | LDG Series | LDG Series | LDG Series | LDG Series |
Converter | None | Compact | Remote | Compact with Battery Power | Insertion |
Accuracy | 0.5% of Rate | 0.5% of Rate | 0.5% of Rate | 1.0% of Rate | 1.5% of the Rate |
Conductivity | >5μs/cm | >5μs/cm | >5μs/cm | >5μs/cm | >5μs/cm |
Min.Velocity | 0.3 m/s | 0.3 m/s | 0.3 m/s | 0.3 m/s | 0.3 m/s |
Max.Velocity | 10 m/s | 10 m/s | 10 m/s | 10 m/s | 10 m/s |
Turndown Ration | Standard 1:20; Others on request | ||||
Output | 4-20mA | 4-20mA/Pulse | 4-20mA/Pulse | Consult the factory | 4-20mA/Pulse |
PowerSupply | (1) 110-240Vac (2) 18-36 Vdc | (1) 110-240Vac (2) 18-36 Vdc | (1) 110-240Vac (2) 18-36 Vdc | Lithium Battery | (1) 110-240Vac (2) 18-36 Vdc (3) Lithium Battery |
Communication | None | Optional: RS485; MODBUS; HART; Profibus-DP | |||
Ex-Proof Level | Exd[ia]qIICT5 | ||||
Protection Level | IP65 | IP65 | Converter: IP65 Sensor: IP65; (IP68 on request) | IP65 | IP65 |
Diameter | DN10-DN1200 | DN200-DN1200 | |||
Installation | 1. Flange (Standard: ISO; Optional: ANSI, DIN, JIS); 2. Thread (Standard: G; Optional: NPT); 3. Wafer: 4. Tri-Clamp for sanitary Type; | Insertion | |||
Pressure Rating | Standard: 1.6Mpa; Others on request | ||||
Fluid Temperature | Standard: PTFE: <120℃ (customized PTF)E: <120℃) ; Rubber: <60℃ | ||||
Ambient Temperature | -30℃-60℃ |