Coriolis mass flow meter/acrylic flow meter
Basic Info
Model No.: CMF
Product Description
1.High accuracy in measurement
2.Working stably and reliably
3.A lot of fluids are applicable
Coriolis mass flow meter acrylic flow meter Table of Technical Specifications (Table 1)
Titles | Technical Specifications |
Mass flow accuracy | ±[0.2% +(zero stability /flow rate×100%)] |
Mass flow repeatability | ±(1/2) ×[0.2% +(zero stability /flow rate×100%)] |
Density range | 0.2 g/cm3~3.5g/cm3 |
Density accuracy | ±0.002g/cm3 |
Temperature range | -60°C~+200°C |
Temperature accuracy | ±1°C |
Output of current loop | 4mA~20mA |
Output of frequency/pulse | 0Hz~10kHz |
Contactor capacity of a Batch Control relay | 24V/0.1A |
Contactor form | normal open |
Titles | Specifications |
Temperature range of fluid | -40°C~+200°C |
Environmental temperature range | 0°C~+40°C |
Environmental humidity | ≤90% RH, non condensation |
Atmospheric pressure range | 86kPa~106kPa |
Power supply of transmitters | Essential safety Voltage: AC(220±10%)V,(50±5%)Hz Composite Voltage: DC (24±10%) V |
Power consumed | <15W |
Specs | Line Sizes (mm) | Flow Range (t/h) | Calibration Range (t/h) | Max. Tube Pressure (MPa) | Zero Stability (t/hr) | Velocity Parameter (h m/t s) |
DN1 | 1 | 0~0.04 | 0.004~0.04 | 30.0 | 0.000008 | 353.7 |
DN3 | 3 | 0~0.35 | 0.035~0.35 | 30.0 | 0.000067 | 39.3 |
DN6 | 6 | 0~0.7 | 0.07~0.7 | 30.0 | 0.00016 | 19.65 |
DN10 | 10 | 0~1.2 | 0.12~1.2 | 30.0 | 0.0002 | 4.912 |
DN15 | 15 | 0~6.4 | 0.64~6.4 | 4.0 | 0.0011 | 2.183 |
DN25 | 25 | 0~16 | 1.6~16 | 4.0 | 0.002 | 0.902 |
DN40 | 40 | 0~40 | 4~40 | 4.0 | 0.003 | 0.334 |
DN50 | 50 | 0~65 | 6.5~65 | 4.0 | 0.006 | 0.197 |
DN80 | 80 | 0~160 | 16~160 | 2.5 | 0.01 | 0.0873 |
DN100 | 100 | 0~250 | 25~250 | 2.5 | 0.015 | 0.0544 |
DN150 | 150 | 0~550 | 55~550 | 2.5 | 0.03 | 0.0239 |
Product Categories : Coriolis Mass Flowmeter